SignalScope X Icon

Room Acoustics Analyzer

Pro

The Room Acoustics Analyzer measures reverberation time and room acoustic parameters.

Documentation

Key Features

RT60 measurement
EDT, T20, T30, T60 calculation
Center time, clarity, definition
Octave and 1/3 octave bands
Integrated impulse response method
Built for Standardized Measurement: SignalScope's Room Acoustics Analyzer computes room acoustics parameters from impulse response data as specified in ISO 3382, Acoustics - Measurement of room acoustics parameters. It employs real-time Order 3 digital Butterworth bandpass filters, in whole or 1/3-octave frequency bands, designed with standard filter characteristics defined by ANSI S1.11 and IEC 61260.
Save Data: Export impulse response (IR) data to an audio file (.wav, .aif, or .caf) or IR data, calculated room acoustics parameter values, and metadata to a data file (.csv, .mat, or .txt). Or, generate a high-resolution image of the graph and save it to a PDF file.

Specifications

  • Impulse Response (IR) Data Source: Any single channel/measurement can be selected from the Oscilloscope or Dual FFT Analyzer tool, or from an Audio or Data File
  • Early Time Cutoff (te): User-definable
  • Normalize IR: Enable/Disable
  • Plot Regression Line: Enable/Disable
  • Bandwidth: Octave, 1/3 octave
  • Supported Sample Rates (samples/second): 44100, 48000, 88200, 96000, 176400, 192000
  • Filter Type: Order 3 Butterworth digital bandpass
Room Acoustics Parameters
  • Reverberation Time (RT60): T20, T30, T60
  • Early Decay Time (EDT)
  • Nonlinearity (ξ): T20, T30, T60, EDT
  • Center Time (Ts)
  • Clarity: C50, C80, Cte
  • Definition: D50, D80, Dte
Nominal Band Center Frequencies (Hz)
  • Whole Octave: 31.5, 63, 125, 250, 500, 1000, 2000, 4000, 8000, 16000
  • 1/3 Octave: 20, 25, 31.5, 40, 50, 63, 80, 100, 125, 160, 200, 250, 315, 400, 500, 630, 800, 1000, 1250, 1600, 2000, 2500, 3150, 4000, 5000, 6300, 8000, 10000, 12500, 16000, 20000
Scale
  • Horizontal divisions: 10 (linear frequency scale)
  • Vertical divisions: 10
  • Autoscale: Off, Auto
  • IR Scale: Lin
  • Squared IR Scale: dB
  • dB Vertical Scale (dB/Div) 0.01, 0.02, 0.03, 0.04, 0.05, 0.06, 0.08, 0.09, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.8, 0.9, 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 9.0, 10.0, 12.0, 15.0, 16.0, 18.0, 20.0, 24.0, 25.0, 27.0, 30.0
  • Lin/Log Magnitude Scale (Units/Div) 1e-9, 2e-9, 3e-9, 4e-9, 5e-9, 6e-9, 8e-9, 10e-9, 20e-9, 30e-9, 40e-9, 50e-9, 60e-9, 80e-9, 100e-9, 200e-9, 300e-9, 400e-9, 500e-9, 600e-9, 800e-9, 1e-6, 2e-6, 3e-6, 4e-6, 5e-6, 6e-6, 8e-6, 10e-6, 20e-6, 30e-6, 40e-6, 50e-6, 60e-6, 80e-6, 100e-6, 200e-6, 300e-6, 400e-6, 500e-6, 600e-6, 800e-6, 1e-3, 2e-3, 3e-3, 4e-3, 5e-3, 6e-3, 8e-3,10e-3, 20e-3, 30e-3, 40e-3, 50e-3, 60e-3, 80e-3,100e-3, 200e-3, 300e-3, 400e-3, 500e-3, 600e-3, 800e-3, 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 8.0, 10.0, 20.0, 30.0, 40.0, 50.0, 60.0, 80.0, 100.0, 200.0, 300.0, 400.0, 500.0, 600.0, 800.0, 1e3, 2e3, 3e3, 4e3, 5e3, 6e3, 8e3, 10e3, 20e3, 30e3, 40e3, 50e3, 60e3, 80e3, 100e3, 200e3, 300e3, 400e3, 500e3, 600e3, 800e3
Cursor
  • Peak Track: Off, Max, Min
  • Horizontal Bar: Enable/Disable
  • Horizontal Bar on Decay Curve: Enable/Disable
  • Set Decay Curve Limits from Cursors: Enable/Disable
Data Export
  • IR Audio File Format: AIF, CAF, WAV
  • Data File Format: CSV, MAT, TXT
  • Image: PDF
  • Exported data files can optionally include parameter data and raw IR data, or only parameter data.
Data Import
  • IR Audio File Format: AIF, CAF, WAV
  • Data File Format: CSV, MAT, TXT (only files created by the Oscilloscope, Dual FFT Analyzer, or Room Acoustics Analyzer tools)
* Specifications subject to change